Educational trainer

PM-ENTERPRISE

Facilitates easy and safe wiring by students due to use of 4mm sturdy shrouded banana patch

cords and shrouded socket arrangements.All machines are mounted on finelypaintedsturdy base frame

Facilitates easy and safe wiring by students due to use of 4mm sturdy shrouded banana patch

cords and shrouded socket arrangements.All machines are mounted on finelypaintedsturdy base frame.

With due emphasis on student safety machines operate upto 300W power levels and upto 1500

RPM, without compromising didactic use Able to draw all graphs.

Break pulley arrangement for variable loading of motor.

Motor specifications

Ph AC .  Integrated motorVoltage: . 230VAC, 50Hz

Capacity: , 750W/4 pole/ 1500RPM/ 10 terminals,

 Rotor construction: Diecast squirrel cage Rotor,

Stator construction: Two windings brought out on 4 terminals for main&auxiliary used to configure different motors split phase, CSCR, CSIR,

Frame/mounting:foot mountain 100 frame, chassis mounted, 19mmshaft dia

Loading arrangement: Friction break pulley (60.5mm dia) for loading arrangement with 20Kg springbalance for torquemeasurement.

Speed Measurement: Using proximity sensor

List of the experiments

1.Study of Speed-Torque Characteristics of Single Phase induction motor (Split phase type).

2) Study of Efficiency and Input power factor of 1 Phase induction motor (Split phase type) for various loading conditions.

3) Study of Speed-Torque Characteristics of Single Phase Induction Motor (Capacitor StartType)

4) Study of Efficiency and Input Power factor of Single Phase induction motor (Capacitor Start Type) for various loading  conditions.

5) Study of SpeedTorque Characteristics of Single Phase Induction Motor (Capacitor Start-RunType).

6) Study of Efficiency and Input power factor of Single Phase induction motor (Capacitor Start-RunType) for various loading conditions.

Electrical panel specifications

Aluminum profile (4X1) sturdy flat panel (table top) system, carrying various high voltage components housed in plastic enclosures (panel) to minimize shock possibility.

  • • 1 Phase Motor, induction Motor Panel

Protection with 1 phase 1 MCBs of 4A/1.6A 1 each

Integrated AC 1 phase wattmeter measurement panel

1] Consist of 1 nos of (96X96mm) Digital meter for 1Phase Measures W (0.2 lag – unity 0.2 lead),W Current specs for 1 phase meter = 5A.

3] Auxiliary supply = 170-250VAC

On board DOL starter module for easy start of the motor

Digital ac voltmeter and ammeter module for voltage & current measurement.