Educational trainer

PM-ENTERPRISE

  • Electrical Control Panel with 1phase (500VA)& 3 Phase 1.5KVA Transformer. (500VA per phase)
  • Panel of Aluminum profile sturdy (4x2) flat panel (table top) system, carrying various high voltage components housed in plastic enclosures (panel) to minimize shock possibility
  • Transformer provided will be high quality copper wound
  • All modules are well screen printed and in modular form for easy changeability depends upon the experiment need.
  • Primary will be 440V and secondary of the transformer will be 220V.
  • Panel consists of MS powder coated housing with back side removable.
  • Transformer will be differently housed in a MS powder cabinet for easy carrying and other general use.
  • It is fitted with appropriate analog or digital voltmeter, ammeter to record the readings.
  • Short circuit protection with the help of MCB.
  • 1 NOS. 4A variable ac supply is provided separately through variac for short circuit test.
  • Load bank is provided separately with mobility and for it can be used for other general use.
  • Connections through 4mm safety terminals
  • Supplied with instruction manual

  1. Load test on three phase transformer
  2. Study of transformer connections in various configurations STAR-DELTA, DELTA-STAR, STAR-STAR, DELTA-DELTA
  3. Ratio and efficiency test.
  4. Polarity test
  5. Open and short circuit test

 

·         Electrical Control Panel with 1phase (500VA)& 3 Phase 1.5KVA Transformer. (500VA per phase)

·         Panel of Aluminum profile sturdy (4x2) flat panel (table top) system, carrying various high voltage components housed in plastic enclosures (panel) to minimize shock possibility

·         Transformer provided will be high quality copper wound

·         All modules are well screen printed and in modular form for easy changeability depends upon the experiment need.

·         Primary will be 440V and secondary of the transformer will be 220V.

·         Panel consists of MS powder coated housing with back side removable.

·         Transformer will be differently housed in a MS powder cabinet for easy carrying and other general use.

·         It is fitted with appropriate analog or digital voltmeter, ammeter to record the readings.

·         Short circuit protection with the help of MCB.

·         1 NOS. 4A variable ac supply is provided separately through variac for short circuit test.

·         Load bank is provided separately with mobility and for it can be used for other general use.

·         Connections through 4mm safety terminals

·         Supplied with instruction manual